Portable ph meter

Portable ph meter
Product Detailed
Related Categories:PH Meters
1.0.01 ph precision 2.Large screen LCD display 3.Waterproof level:IP67 4.Automatic temperature compensation 5.Renewable

Display screen

LCD 

Measuring range

0.00-14.00 PH

Precision

+/-0.01PH

Resolution

0.01PH

Calibration

Automatic three point calibration

(4.00; 6.86; 9.18)

Operation  temperature

0---60°C

Automatic temperature compensation

0—60°C

With  DC1.5V(AG13*3pcs)

Low Battery Indicator

5 minutes automatic shutdown function

Size 

183mm*38mm*38mm

Weight 

80g

Use steps: 

1.  Please unplug the electrode protective sleeve before use.

2.  Clean the electrode with distilled water ,and dry it with filter paper. 

3   Press the switch. Switch on the power supply.

4.  Immerse the electrode into the test solution 

5.  Read the digital after the numerically stable.It displays temperature value  below screen.

6.  Press the switch after finishing reading. Wipe clean the electrode before sleeving it.

 Calibration

 1.  Put proper 6.86, 4.00 and 9.18 standard solution apart in clean 

     beakers  

2.  In order to accurate calibration , put every buffer apart in two 

     beakers.One for cleaning the electrode and the other for calibration. 

3.  Press the switch,switch on the power supply.

4.  Press "shift" button. wait until there is "6.86" digital  and "---°C"   

     symbol. Immerse the electrode in PH 6.86  standard buffer solution  

     and gently  shake the electrode until the display digital same as   

    6.86 ph of the standard solution and "----°C" display temperature.Then 

    complete the PH 6.86 point   calibration

5. Clean the electrode with distilled water and dry it with filter  

     paper.Press "shift" button and repeat Step 4.

     Complete the ph 4.00 point calibration

6. Clean the electrode with distilled water and dry it with filter paper. Put   

    the electrode into 9.18 standard solution and gently shake it until 

    displaying the stable digital.Display value is in the range of allowable  

    error.

7. This instrument calibration work is completed after all the six 

    steps.

Automatic temperature compensation: 

The instrument with automatic temperature compensation function under measurement mode. 

Maintenance

Keep the electrode clean, cover the electrode protective sleeve, please take out the batteries for long periods idle.

Low Battery Indicator

Please replace the battery if the battery symbol flashing in the upper-right corner 

Warranty: 

Product warranty life time from the date of purchase

The following situations are not in the range of warranty, damage caused by misemploy (battery leakage, water into circuit boards etc.) physical abuse, the label tore.

Note 

1.The instrument is a professional instrument, please use under professionals instructions in order to avoid instrument failure 

2. Please immerse the electrode in clear water. 

  Soak time: 5-10 minutes

3. Don't put the PH meter insert liquid too deep but immerse the electrode . Before use, confirm the PH electrode fixed ring is steady in order not to damage circuit board